Engineering Manual
16 Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04
5 More Advanced Functions
a) The Chime FacilityThe 'C' key can be used to select the 'chime' facility
while the system is Unset.
For example, an alert is to sound if someone enters through a particular door
during the day.
NOVAR PLC
TIME:
Press the 'C' key.
The display will show a 'C'
NOVAR PLC
TIME: C
If the door opens the 'chime' tone will occur.
To cancel the 'Chime' function, press 'C' again.
NOVAR PLC
TIME:
a) Ignoring an Open Door or Window
In a domestic setting it may be necessary to ignore windows deliberately left
open in the summer-time.
Enter the PIN code or present the tag.