ADE Accenta G3 Specifiche Pagina 37

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 56
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 36
Accenta/Optima Engineer’s Manual
33
Omit Allow & Double Knock
LED Keypad:
Press [CHIME] to toggle omit allow status on or off.
Press [9] to turn all omit allow zones on.
Press [0] to turn all omit allow zones off.
Press [OMIT] to enter into menu. LED 2 is on.
Press [2] to select Omit Allow.
Press zone number [1-8] to choose a particular zone.
Press the [zone number] or [CHIME] to toggle the omit allow
status on or off. The appropriate LED is on when the zone is
set up as omit allow. Default settings are off.
Press [RESET] twice to leave the menu.
[OMIT]
[2]
[1-8] or [CHIME]
[RESET]
12
3
4
5
6
7
8
12
3
4
5
6
7
8
12
3
4
5
6
7
8
12
3
4
5
6
7
8
Vedere la pagina 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 ... 55 56

Commenti su questo manuale

Nessun commento